| MODEL | 
    ALP-10K | 
    ALP-20K | 
    ALP-30K | 
    ALP-40K | 
    ALP-50K | 
    ALP-60K | 
   
  
    | Phase | 
    3-Phase Input / 3-Phase 
      Output | 
   
  
    | kVA | 
    10 | 
    20 | 
    30 | 
    40 | 
    50 | 
    60 | 
   
  
    | INPUT (RECTIFIER) | 
    
   
  
    | Input Voltage | 
    380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
Special specification can be customized | 
   
  
    | Input Range | 
    ± 20% ( > ± 20% is available upon request) | 
   
  
    | Input Frequency | 
    50/60 Hz ± 7% | 
   
  
    | Power Walk In | 
    15% ~ 100% : 15 sec | 
   
  
    | Efficiency | 
    99% | 
   
  
    | Voltage Regulation | 
    1% | 
   
  
    | BATTERY | 
     
  
    | Battery Type/Pcs | 
    Maintenance free lead-acid batteries/12V x 29pcs | 
   
  
    | Battery Start | 
    Yes, UPS can be started without AC source | 
   
  
    | INVERTER | 
     
  
    | Output Voltage | 
    380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
Special specification can be customized | 
   
  
    | Wave Form | 
    Sine wave | 
   
  
    | Output Power Factor | 
    0.8 | 
   
  
    | Frequency Lock Range | 
    45~55Hz/55~65Hz | 
   
  
    Output Frequency 
      (Free Running) | 
    50/60 Hz ± 0.1 Hz | 
   
  
    Phase Shift Under 100%  
      Unbalance Load | 
    120°±0.5° | 
   
  
    | THD (Linear Load) | 
    < 3 % | 
   
  
    | Overload
         | 
    < 110% | 
    Continuous | 
   
  
    | 110 ~ 124% | 
    15 minutes | 
   
  
    | 125 ~ 149% | 
    5 minutes | 
   
  
    | ≧ 150% | 
    30 seconds | 
   
  
    Efficiency(100% Load) 
for 380/400/415V,3P4W | 
    92% | 
    93.5% | 
    94% | 
     
  
    | STATIC SWITCH | 
     
  
    | Voltage Range | 
    173 ~ 277 Vac (L-N) | 
   
  
    | Main to Inverter | 
    0 ms | 
   
  
    | OVERALL CHARACTERISTICS | 
     
  
    Overall Efficiency(100% Load) 
for 380/400/415V,3P4W | 
    90% | 
    91% | 
    92% | 
     
  
    | Dimensions(W*H*D)mm | 
    550 * 1600  * 800 | 
   
  
    Weight
      (Kg, without battery) 
      for 380/400/415V, 3P4W | 
    300 | 
    400 | 
    470 | 
    520 | 
    560 | 
    630 | 
   
  
    | Audible Noise(At 1M) | 
    < 63 dBA  | 
    < 65 dBA | 
     
  
    | Temperature | 
    0  ~  40℃ ( 32  ~  104℉ ) | 
   
  
    | Humidity | 
    0% ~ 90% (non-condensing) | 
   
  
    | Altitude | 
    < 1500M above sea level | 
   
  
    | EN50091-1,-2 | 
    Yes | 
   
  
    | Short Circuit Protection | 
    Yes | 
   
  
    | Lightning/EMC Filter | 
    MOV/Input&Output (FCC CLASS A) | 
   
  
    | Galvanic Isolation | 
    Input&Output true galvanic isolation | 
   
  
    | LED,LCD,Buzzer | 
    Yes | 
   
  
    Remote Control/  
      Communication Interface | 
    Monitoring 1~99 UPS simultaneously/Dry contact, RS232, RS485 | 
   
  
    ✽ Different specifications required are available 
      ✽ All specifications mentioned above are subject to change without prior notice | 
   
 
                
              
			
			  
				
			 
			
           
            
  
    | MODEL | 
    ALP-80K | 
    ALP-100K | 
    ALP-120K | 
    ALP-160K | 
   
  
    | Phase | 
    3-Phase Input / 3-Phase 
      Output | 
   
  
    | kVA | 
    80 | 
    100 | 
    120 | 
    160 | 
   
  
    | INPUT (RECTIFIER) | 
     
  
    | Input Voltage | 
    380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
      Special specification can be customized | 
     
  
    | Input Range | 
    ± 20% ( > ± 20% is available upon 
      request) | 
   
  
    | Input Frequency | 
    50/60 Hz ± 7% | 
   
  
    | Power Walk In | 
    15% ~ 100% : 15 sec | 
   
  
    | Efficiency | 
    99% | 
   
  
    | Voltage Regulation | 
    1% | 
   
  
    | BATTERY | 
     
  
    | Battery Type/Pcs | 
    Maintenance free lead-acid batteries/12V x 29pcs | 
   
  
    | Battery Start | 
    Yes, UPS can be started without AC source | 
   
  
    | INVERTER | 
     
  
    | Output Voltage | 
    380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
Special specification can be customized | 
     
  
    | Wave Form | 
    Sine wave | 
   
  
    | Output Power Factor | 
    0.8 | 
   
  
    | Frequency Lock Range | 
    45~55Hz/55~66Hz | 
   
  
    Output Frequency 
      (Free Running) | 
    50 / 60 Hz ± 0.1 Hz | 
   
  
    Phase Shift Under 100%  
      Unbalance Load | 
    120°±0.5° | 
   
  
    | THD (Linear Load) | 
    < 3 % | 
   
  
    | Overload
         | 
    < 110% | 
    Continuous | 
   
  
    | 110 ~ 124% | 
    15 minutes | 
   
  
    | 125 ~ 149% | 
    5 minutes | 
   
  
    | ≧ 150% | 
    30 seconds | 
   
  
    Efficiency (100% Load) 
      for 380/400/415V, 3P4W | 
    94.5% | 
    95% | 
     
  
    | STATIC SWITCH | 
     
  
    | Voltage Range | 
    173 ~ 277 Vac (L-N) | 
   
  
    | Main to Inverter | 
    0 ms | 
   
  
    | OVERALL CHARACTERISTICS | 
     
  
    Overall Efficiency(100% Load) 
      for 380/400/415V, 3P4W | 
    92.5% | 
    93% | 
     
  
    | Dimensions(W*H*D)mm | 
    1100*1600*800 | 
   
  
    Weight (Kg, without battery) 
      for 380/400/415V, 3P4W | 
    950 | 
    1250 | 
    1400 | 
    1600 | 
   
  
    | Audible Noise(At 1M) | 
    < 67 dBA | 
   
  
    | Temperature | 
    0  ~  40℃ ( 32  ~  104℉ ) | 
   
  
    | Humidity | 
    0% ~ 90% (non-condensing) | 
   
  
    | Altitude | 
    < 1500M above sea level | 
   
  
    | EN50091-1,-2 | 
    Yes | 
   
  
    | Short Circuit Protection | 
    Yes | 
   
  
    | Lightning/EMC Filter | 
    MOV/Input&Output (FCC CLASS A) | 
   
  
    | Galvanic Isolation | 
    Input&Output true galvanic isolation | 
   
  
    | LED,LCD,Buzzer | 
    Yes | 
   
  
    Remote Control/  
      Communication Interface | 
    Monitoring 1~99 UPS simultaneously/Dry contact, RS232, RS485 | 
   
  
    ✽ Different specifications required are available 
      ✽ All specifications mentioned above are subject to change without prior notice | 
   
 
			
             
            
            
            
			  
				
  
    | MODEL | 
    ALP-240K | 
    ALP-320K | 
    ALP-400K | 
   
  
    | Phase | 
    3-Phase Input / 3-Phase 
      Output | 
   
  
    | KVA | 
    240 | 
    320 | 
    400 | 
   
  
    | INPUT (RECTIFIER) | 
     
  
    | Input Voltage | 
    380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
Special specification can be customized | 
   
  
    | Input Range | 
    ± 20% ( > ± 20% is available upon 
      request) | 
   
  
    | Input Frequency | 
    50/60 Hz ± 7% | 
   
  
    | Power Walk In | 
    15% ~ 100% : 15 sec | 
   
  
    | Efficiency | 
    99% | 
   
  
    | Voltage Regulation | 
    1% | 
   
  
    | BATTERY | 
     
  
    | Battery Type/Pcs | 
    Maintenance free lead-acid batteries/12V x 29pcs | 
   
  
    | Battery Start | 
    Yes, UPS can be started without AC source | 
   
  
    | INVERTER | 
     
  
    | Output Voltage | 
    380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
Special specification can be customized | 
   
  
    | Wave Form | 
    Sine wave | 
   
  
    | Output Power Factor | 
    0.8 | 
   
  
    | Frequency Lock Range | 
    45~55Hz/55~65Hz | 
   
  
    Output Frequency 
      (Free Running) | 
    50/60 Hz ± 0.1 Hz | 
   
  
    Phase Shift Under 100%  
      Unbalance Load | 
    120°±0.5° | 
   
  
    | THD (Linear Load) | 
    < 3 % | 
   
  
    | Overload
         | 
    < 110% | 
    Continuous | 
   
  
    | 110 ~ 124% | 
    15 minutes | 
   
  
    | 125 ~ 149% | 
    5 minutes | 
   
  
    | ≧ 150% | 
    30 seconds | 
   
  
    Efficiency (100% Load) 
     for 380/400/415V, 3P4W | 
    95% | 
     
  
    | STATIC SWITCH | 
     
  
    | Voltage Range | 
    173 ~ 277 Vac (L-N) | 
   
  
    | Main to Inverter | 
    0 ms | 
   
  
    | OVERALL CHARACTERISTICS | 
     
  
    Overall Efficiency(100% Load) 
      for 380/400/415V, 3P4W | 
    93% | 
     
  
    | Dimensions(W*H*D)mm | 
    2240 * 1600  * 800 | 
    2220  * 1900 * 1000 | 
   
  
    Weight (Kg, without battery) 
      for 380/400/415V, 3P4W | 
    2700 | 
    3000 | 
    3600 | 
   
  
    | Audible Noise(At 1M) | 
    < 70 dBA | 
    < 72 dBA | 
   
  
    | Temperature | 
    0  ~  40℃ ( 32  ~  104℉ ) | 
   
  
    | Humidity | 
    0% ~ 90% (non-condensing) | 
   
  
    | Altitude | 
    < 1500M above sea level | 
   
  
    | EN50091-1,-2 | 
    Yes | 
   
  
    | Short Circuit Protection | 
    Yes | 
   
  
    | Lightning/EMC Filter | 
    MOV/Input&Output (FCC CLASS A) | 
   
  
    | Galvanic Isolation | 
    Input&Output true galvanic isolation | 
   
  
    | LED,LCD,Buzzer | 
    Yes | 
   
  
    Remote Control/  
      Communication Interface | 
    Monitoring 1~99 UPS simultaneously/Dry contact, RS232, RS485 | 
   
  
    ✽ Different specifications required are available 
      ✽ All specifications mentioned above are subject to change without prior notice | 
   
 
			
             
             
              
            
              
               
                
                  | MODEL | 
                   ALP-500K | 
                  ALP-600K | 
                  ALP-700K | 
                  ALP-800K | 
                 
                
                  | Phase | 
                  3-Phase Input / 3-Phase Output | 
                 
                
                  | kVA  | 
                  500 | 
                  600 | 
                  700 | 
                  800 | 
                 
                
                  | INPUT(RECTIFIER) | 
                   
                
                  | Input Voltage  | 
                  380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
Special specification can be customized | 
                 
                
                  | Input Range  | 
                  ± 20% ( > ± 20% is available upon 
      request) | 
                 
                
                  | Input Frequency | 
                  50/60Hz ± 7%  | 
                 
                
                  | Power Walk In  | 
                  15% ~ 100%: 15 sec  | 
                 
                
                  | Efficiency  | 
                  99% | 
                 
                
                  | Voltage Regulation  | 
                  1%  | 
                 
                
                  | BATTERY   | 
                 
                
                  | Battery Type/Pcs | 
                  Maintenance free lead-acid  batteries/12V x 29pcs | 
                 
                
                  | Battery Start | 
                  Yes, UPS can be started without AC source | 
                 
                
                  | INVERTER   | 
                 
                
                  | Output Voltage | 
                  380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
                    Special specification can be customized | 
                 
                
                  | Wave Form  | 
                  Sine wave | 
                 
                
                  | Output Power Factor | 
                  0.8 | 
                 
                
                  | Frequency Lock    Range  | 
                  45 ~ 55Hz/55 ~ 65Hz | 
                 
                
                  | Output Frequency (Free Running)  | 
                  50/60Hz ± 0.1Hz | 
                 
                
                  Phase Shift Under    100% 
Unbalance load  | 
                  120゚± 0.5゚ | 
                 
                
                  | THD (Linear load)  | 
                  < 3% | 
                 
                
                  | Overload  | 
                  < 110%  | 
                  Continuous | 
                 
                
                  | 110~124%  | 
                  15 minutes | 
                 
                
                  | 125~149%  | 
                  5 minutes | 
                 
                
                  | ≧150% | 
                  30 seconds | 
                 
                
                  Efficiency (100% Load) 
for 380/400/415V, 3P4W  | 
                  95%  | 
                 
                
                  | STATIC SWITCH   | 
                   
                
                  | Voltage Range  | 
                  173 ~ 277Vac (L-N)  | 
                 
                
                  | Main to Inverter  | 
                  0 ms  | 
                 
                
                  | OVERALL    CHARACTERISTICS   | 
                 
                
                  Overall Efficiency(100% Load) 
                    for 380/400/415V, 3P4W | 
                  93% | 
                 
                 
                  | Dimensions(W*H*D)mm | 
                  3340*1900*1000 | 
                  4460*1900*1000 | 
                 
                
                  Weight (Kg, without battery) 
for 380/400/415V, 3P4W | 
                  4500 | 
                  6000 | 
                  6800 | 
                  7500 | 
                 
                
                  | Audible Noise(At 1M) | 
                  < 75 dBA  | 
                  < 80 dBA  | 
                 
                
                  | Temperature  | 
                  0  ~ 40゚C ( 32 ~ 104゚F ) | 
                 
                
                  | Humidity | 
                  0% ~ 99% (non-condensing)  | 
                 
                
                  | Altitude | 
                  < 1500M above sea level  | 
                 
                
                
                  | EN50091-1,2 | 
                  Yes  | 
                 
                
                  | Short Circuit Protection | 
                  Yes | 
                 
                
                  | Lightning/EMC    Filter | 
                  MOV/Input&Output(FCC CLASS A) | 
                 
                
                  | Galvanic    Isolation  | 
                  Input&Output true galvanic isolation | 
                 
                
                  | LED, LCD,    Buzzer  | 
                  Yes | 
                 
                
                  Remote Control/  
Communication Interface | 
                  Monitoring 1~99 UPS simultaneously/Dry contact, RS232, RS485 | 
                 
                
                  ✽ Different specifications required are available 
                    ✽ All specifications mentioned above are subject to change without prior    notice | 
                 
               
            
             
            
             
            
			
  
    | MODEL | 
    ALP-10K | 
    ALP-20K | 
    ALP-30K | 
    ALP-40K | 
    ALP-50K | 
    ALP-60K | 
   
  
    | Phase | 
    3-Phase Input / 1-Phase 
      Output | 
   
  
    | kVA | 
    10 | 
    20 | 
    30 | 
    40 | 
    50 | 
    60 | 
   
  
    | INPUT (RECTIFIER) | 
    
   
  
    | Input Voltage | 
    380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
Special specification can be customized | 
   
  
    | Input Range | 
    ± 20% ( > ± 20% is available upon request) | 
   
  
    | Input Frequency | 
    50/60 Hz ± 7% | 
   
  
    | Power Walk In | 
    15% ~ 100% : 15 sec | 
   
  
    | Efficiency | 
    99% | 
   
  
    | Voltage Regulation | 
    1% | 
   
  
    | BATTERY | 
     
  
    | Battery Type/Pcs | 
    Maintenance free lead-acid batteries/12V x 29pcs | 
   
  
    | Battery Start | 
    Yes, UPS can be started without AC source | 
   
  
    | INVERTER | 
     
  
    | Output Voltage | 
    220/230/240V, single phase, Special voltage can be customized | 
   
  
    | Wave Form | 
    Sine wave | 
   
  
    | Output Power Factor | 
    0.8 | 
   
  
    | Frequency Lock Range | 
    45~55Hz/55~65Hz | 
   
  
    Output Frequency 
      (Free Running) | 
    50/60 Hz ± 0.1 Hz | 
   
  
    Phase Shift Under 100%  
      Unbalance Load | 
    120°±0.5° | 
   
  
    | THD (Linear Load) | 
    < 3 % | 
   
  
    | Overload
         | 
    < 110% | 
    Continuous | 
   
  
    | 110 ~ 124% | 
    15 minutes | 
   
  
    | 125 ~ 149% | 
    5 minutes | 
   
  
    | ≧ 150% | 
    30 seconds | 
   
  
    Efficiency(100% Load) 
for 380/400/415V,3P4W | 
    92% | 
    93.5% | 
    94% | 
     
  
    | STATIC SWITCH | 
     
  
    | Voltage Range | 
    173 ~ 277 Vac (L-N) | 
   
  
    | Main to Inverter | 
    0 ms | 
   
  
    | OVERALL CHARACTERISTICS | 
     
  
    Overall Efficiency(100% Load) 
for 380/400/415V,3P4W | 
    90% | 
    91% | 
    92% | 
     
  
    | Dimensions(W*H*D)mm | 
    550 * 1600  * 800 | 
   
  
    Weight
      (Kg, without battery) 
      for 380/400/415V, 3P4W | 
    300 | 
    400 | 
    470 | 
    520 | 
    560 | 
    630 | 
   
  
    | Audible Noise(At 1M) | 
    < 63 dBA  | 
    < 65 dBA | 
     
  
    | Temperature | 
    0  ~  40℃ ( 32  ~  104℉ ) | 
   
  
    | Humidity | 
    0% ~ 90% (non-condensing) | 
   
  
    | Altitude | 
    < 1500M above sea level | 
   
  
    | EN50091-1,-2 | 
    Yes | 
   
  
    | Short Circuit Protection | 
    Yes | 
   
  
    | Lightning/EMC Filter | 
    MOV/Input&Output (FCC CLASS A) | 
   
  
    | Galvanic Isolation | 
    Input&Output true galvanic isolation | 
   
  
    | LED,LCD,Buzzer | 
    Yes | 
   
  
    Remote Control/  
      Communication Interface | 
    Monitoring 1~99 UPS simultaneously/Dry contact, RS232, RS485 | 
   
  
    ✽ Different specifications required are available 
      ✽ All specifications mentioned above are subject to change without prior notice | 
   
 
            
            
             
            
           
            
  
    | MODEL | 
    ALP-80K | 
    ALP-100K | 
    ALP-120K | 
    ALP-160K | 
   
  
    | Phase | 
    3-Phase Input / 1-Phase 
      Output | 
   
  
    | kVA | 
    80 | 
    100 | 
    120 | 
    160 | 
   
  
    | INPUT (RECTIFIER) | 
     
  
    | Input Voltage | 
    380/220V, 400/230V, 415/240V(3 phase, 4-wire),  
      Special specification can be customized | 
     
  
    | Input Range | 
    ± 20% ( > ± 20% is available upon 
      request) | 
   
  
    | Input Frequency | 
    50/60 Hz ± 7% | 
   
  
    | Power Walk In | 
    15% ~ 100% : 15 sec | 
   
  
    | Efficiency | 
    99% | 
   
  
    | Voltage Regulation | 
    1% | 
   
  
    | BATTERY | 
     
  
    | Battery Type/Pcs | 
    Maintenance free lead-acid batteries/12V x 29pcs | 
   
  
    | Battery Start | 
    Yes, UPS can be started without AC source | 
   
  
    | INVERTER | 
     
  
    | Output Voltage | 
    220/230/240V, single phase, Special voltage can be customized | 
     
  
    | Wave Form | 
    Sine wave | 
   
  
    | Output Power Factor | 
    0.8 | 
   
  
    | Frequency Lock Range | 
    45~55Hz/55~66Hz | 
   
  
    Output Frequency 
      (Free Running) | 
    50 / 60 Hz ± 0.1 Hz | 
   
  
    Phase Shift Under 100%  
      Unbalance Load | 
    120°±0.5° | 
   
  
    | THD (Linear Load) | 
    < 3 % | 
   
  
    | Overload
         | 
    < 110% | 
    Continuous | 
   
  
    | 110 ~ 124% | 
    15 minutes | 
   
  
    | 125 ~ 149% | 
    5 minutes | 
   
  
    | ≧ 150% | 
    30 seconds | 
   
  
    Efficiency (100% Load) 
      for 380/400/415V, 3P4W | 
    94.5% | 
    95% | 
     
  
    | STATIC SWITCH | 
     
  
    | Voltage Range | 
    173 ~ 277 Vac (L-N) | 
   
  
    | Main to Inverter | 
    0 ms | 
   
  
    | OVERALL CHARACTERISTICS | 
     
  
    Overall Efficiency(100% Load) 
      for 380/400/415V, 3P4W | 
    92.5% | 
    93% | 
     
  
    | Dimensions(W*H*D)mm | 
    1100*1600*800 | 
   
  
    Weight (Kg, without battery) 
      for 380/400/415V, 3P4W | 
    950 | 
    1250 | 
    1400 | 
    1600 | 
   
  
    | Audible Noise(At 1M) | 
    < 67 dBA | 
   
  
    | Temperature | 
    0  ~  40℃ ( 32  ~  104℉ ) | 
   
  
    | Humidity | 
    0% ~ 90% (non-condensing) | 
   
  
    | Altitude | 
    < 1500M above sea level | 
   
  
    | EN50091-1,-2 | 
    Yes | 
   
  
    | Short Circuit Protection | 
    Yes | 
   
  
    | Lightning/EMC Filter | 
    MOV/Input&Output (FCC CLASS A) | 
   
  
    | Galvanic Isolation | 
    Input&Output true galvanic isolation | 
   
  
    | LED,LCD,Buzzer | 
    Yes | 
   
  
    Remote Control/  
      Communication Interface | 
    Monitoring 1~99 UPS simultaneously/Dry contact, RS232, RS485 | 
   
  
    ✽ Different specifications required are available 
      ✽ All specifications mentioned above are subject to change without prior notice | 
   
 
			
             
            
            
		 
	   |