Products > New Products >X1-602/123



UPS
 

Features

Use low voltage battery 12Vdc, ensure home/office safety
Utility + Inverter + Charger + Transfer Switch: all in one
Output power factor 1
Un-limited battery back-up time
Large charger capacity with PFC (0.98)
Charge current (10A - 50A) programmable
High efficiency, low heat dissipation save energy
Hi-frequency line-interactive design (5 countries pattern)
Input and Output isolation (battery mode)
Have DC start & self-diagnostic function
Input voltage range programmable
Generator compatible, no limitation on type of load
LCD control panel
Design to operate under harsh environment

MODEL X1-602 X1-123
Capacity VA/Watt 600VA/600W 1.2kVA/1.2kW(2X0V)
1kVA/1kW (1X0V)
INPUT
Nominal Voltage 100/110/115/120Vac or 208/220/230/240Vac
Voltage Range Wide & narrow voltage range selectable (Default: narrow range)
Wide : 55Vac ~ 150Vac or 110Vac ~ 300Vac
Narrow : 90Vac ~ 130Vac or 180Vac ~ 260Vac
High Voltage Transfer
(Wide / Narrow)
150Vac ± 5% / 130Vac ± 5%; 300Vac ± 5% / 260Vac ± 5%
High Voltage Return
(Wide / Narrow)
145Vac ± 5% / 125Vac ± 5%; 290Vac ± 5% / 250Vac ± 5%
Low Voltage Transfer
(Wide / Narrow)
55Vac ± 5% / 90Vac ± 5%; 110Vac ± 5% / 180Vac ± 5%
Low Voltage Return
(Wide / Narrow)
60Vac ± 5% / 95Vac ± 5%; 120Vac ± 5% / 190Vac ± 5%
Frequency Range 40 ~ 63 Hz (Auto sensing)
Phase Single phase with ground
 OUTPUT
Waveform Pure sine wave
Voltage 100/110/115/120Vac or 208/220/230/240Vac
Voltage Regulation 
(Battery. Mode)
± 1 % RMS for entire battery voltage range 
Frequency Regulation Line Mode Synchronize to AC main
Battery Mode 50 Hz / 60Hz ± 0.1 Hz
Power Factor 1
Current Crest Ratio 3:1
Efficiency Line Mode > 98%
Battery Mode > 85%
Overload Protection Line mode : > 110%, then buzzer alarm and amber LED blink continuously
Battery. mode : 110%-120%: 10s, >120% : 200ms then UPS shutdown
 
Harmonic Distortion ≦ 3% (Linear load), ≦ 6% (Non-linear load)
Transfer Time 4 ms (Typical) / 8 ms (Max)
DC START
Cold Start Yes
BATTERY
Voltage 12Vdc
Type Depending on the capacity of external batteries
CHARGING
Current(for 12Vdc Battery) High and low charging current range selectable ( Default: low range)
Hi:(AC Wide / Narrow Voltage) Max : 20A / 35A Max : 30A / 55A(2X0V)
Max : 10A / 20A(1X0V)
Low:(AC Wide / Narrow Voltage) Max : 10A / 15A Max : 15A / 20A(2X0V)
Max : 5A / 6A(1X0V)
Voltage 13.6Vdc ± 0.2V
Efficiency > 82 %
Power Factor > 0.98
DISPLAY 
LCD UPS status, I/P&O/P voltage/frequency, load level, battery voltage
LED Normal (Green), Warning (Amber), Fault (Red)
AUDIBLE ALARM
Battery Mode Beeping every 4 seconds
Low Battery Beeping every second
UPS Fault Beeping continuously
Overload Beeping twice per second
COMMUNICATION PORT
Standard Configuration HID (Human Interface Device)
ENVIRONMENT
Operation Temperature 0-40 ℃(32-104 ℉)
Relative Humidity 0-95% (non-condensing)
Audible Noise (At 1M) < 55dBA
PHYSICAL
Dimensions(WxHxD)mm 225*101*335
Net Weight(Kg) 4 4.6
✽ 2X0V:208/220/230/240Vac
✽ 1X0V:100/110/115/120Vac
✽ All specifications mentioned above are sujbect to change without prior notice
Download Brochure
X1 602/123 Series